Enerzone

SBI Enerzone pellet, multi-fuel, and woodstove replacement parts. We offer a convection fan kit, auger motors, gaskets, safety switches, igniter element, and burnpot scraper tools.

Showing 1–16 of 32 results

  • Pellethead Black Coal Hod Scuttle Bucket *Open Box*

    $40.00
    Add to cart
  • Pellethead Black Coal Hod Scuttle Bucket

    $49.95
    Add to cart
  • Pellethead Distressed Copper Coal Hod Scuttle Bucket

    $47.95
    Add to cart
  • Pellethead Galvanized Coal Hod Scuttle Bucket

    $49.95
    Add to cart
  • Pellethead Antique Bronze Coal Hod Scuttle Bucket

    $49.95
    Add to cart
  • Pellethead Ash Vacuum Pro

    $149.00
    Add to cart
  • Sale!

    Pellethead Ash Vault Pro Mini

    $75.00
    Read more
  • Pellethead Replacement Drolet, Enerzone, Flame, Osburn, PSG Pellet Stove Auger Feed Motor, 1 RPM Clockwise

    $46.99
    Add to cart
  • Drolet, Enerzone, Flame, Osburn, PSG Pellet Stove Auger Feed Motor, 1 RPM Clockwise, Aftermarket

    $79.00
    Add to cart
  • Stove Bright Satin Black, High Temperature Brush On Paint, 16oz

    $22.95
    Read more
  • Stove Bright Charcoal, High Temperature Brush On Paint, 16oz

    $24.95
    Add to cart
  • SBI Drolet, Enerzone, Flame, Osburn, PSG Pellet Stove Pressure Vacuum Switch Tubing Hose

    $12.95
    Add to cart
  • Stove Bright Metallic Black, High Temperature Brush On Paint, 16oz

    $24.95
    Add to cart
  • Stove Bright Metallic Brown, High Temperature Brush On Paint, 16oz

    $24.95
    Add to cart
  • Stove Bright Goldenfire Brown, High Temperature Brush On Paint, 16oz

    $24.95
    Add to cart
  • Universal Stove & Fireplace Burnpot Cleanout Tool, Firepot Scraper, Aftermarket

    $23.99
    Add to cart

The Enerzone Destination 2.3, Destination Insert 2.3, Solution 1.6, and Solution 1.8 insert woodstove models will use a 5/8″ diameter round rope gasket for the firebox door, part AC06500. For efficiency and safety it's important to inspect your door gasket seal during your routine maintenance to ensure it's making a tight seal all the way around. When it's time to replace your door gasket, you can follow along with our installation video below.

The Enerzone Bio-35 Insert, Bio-35 MF, Bio-45 MF, Euromax, and Eurozone pellet stoves along with Destination and Solution woodstove models will use a 3/4″ flat tape glass gasket for the window channel glass gasket, part AC06400. This gasket creates the seal from the firebox door glass to the door frame. Inspect this gasket during your routine maintenance and replace when there are signs of wear, fray, or air gaps. Follow along for replacement with our installation video below.

The Enerzone Bio-35 Insert, Bio-35 MF, Bio-45 MF, Euromax, and Eurozone pellet stoves and multi-fuel models will use a 1 RPM auger feed motor, part 44038. The auger motor churns pellets up the auger shaft dropping them down the feed chute and into the burnpot/firepot grate. As the auger motor wears over time we will often notice abnormal noises from the motor, frequent auger jams, and inconsistent fuel delivery. See our videos below for general auger motor installation and learn how to test your auger motor direct by making a test cord.

We offer an aftermarket igniter element for the Enerzone Bio-35MF, Bio-35 Insert, and Bio-45MF models replacing SBI part number 44030. Be sure to review the models tab and serial number specifications. The igniter element is located in the burnpot area. During start-up, the igniter will get cherry hot and the combustion air rushing around the igniter becomes 'super-heated' creating ignition to the pellet fuel in the burnpot. As the igniter gets weak over time we will often notice missed ignition cycles or the element not functioning at all. Keep in mind it's the air rushing around the igniter lighting the fire. If there is air loss or air blockage issues in your Enerzone, there will be ignition issues.

If you are experiencing ignition troubles with your stove, check the simple things first

  • Burnpot is clean and seated properly
  • Front door and ash door are closed and the gasket seal is tight all the way around
  • Ash accumulation in the stove and exhaust venting has removed/cleaned out
  • Air intake passageway is free and clear
  • Combustion blower is running at proper voltage

You can also use a basic multi-meter to test the ohms on your igniter element to determine if it's in proper range. Watch our helpful guide videos below on igniter testing and common igniter replacement and installation.

Enerzone pellet stoves will have a low limit switch, high limit switch, and a vacuum pressure air switch which are all designed as safety features. Depending on the model there will be variances in the types of switches; be sure to reference your part number and model notes in our listings. The vacuum switch detects pressure inside the exhaust venting and firebox. If pressure is lost, it will trip and shut down power to the fuel feed auger.

See our helpful videos below for troubleshooting and learning more about how the limit switches and vacuum switches function in your stove.

If you have an Enerzone Bio-45MF (Model EP00045-1 w/Serial Number 100 – 924), we offer an aftermarket blower kit for replacement of the convection fan/distribution blower. Also referred to as the room-air blower, the convection fan circulates air through the heat exchange tubes, delivering the warm air into your room. See our videos below for general cleaning and replacement, along with installation of the blower kit.

Looking for a part for your Enerzone you can't find? Please contact us for order inquires; we are expanding our parts selection for Enerzone.